the best 3 mm peripheral stent

DEVICE GUIDE > Self-Expanding Stents - Endovascular …

Endovascular Today is a publiion dedied to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field. Our Editorial Advisory Board is composed of the top endovascular specialists, including

ABBOTT S-65-080-120-P6 Supera Peripheral Stent …

The Supera peripheral stent occupies a unique class of stent technology. With the Supera stent’s ability to mimic the anatomy''s natural movement while optimizing luminal gain, healthcare professionals find this vascular stent effective when treating the dynamic

Eluvia™ peripheral stent system for the treatment of …

peripheral stent system for the treatment of peripheral lesions above the knee (Rutherford class 2 to 4) with reference vessel diameter of 3 to 7 mm and lesion/occlusion length ≤ 15 cm. Endpoints included primary patency rate, target lesion Walking

Paclitaxel Drug-Eluting Stents in Peripheral Arterial …

1/11/2015· Peripheral arterial disease is a condition in which atherosclerotic plaques partially or completely block blood flow to the legs. Although percutaneous transluminal angioplasty and metallic stenting have high immediate success rates in treating peripheral arterial disease, long-term patency and

Peripheral Stent - Self Expanding Stent System …

0.014” guidewire compatible Nylon copolymer balloon provides semicompliant expansion of the lesion and the stent High radial strength peripheral stent (80-100 KN/sqm) Stent strut width is 175 microns, strut thickness is 165 microns No foreshortening of stent up to

S balloon-expandable stents

3.5, 4 10, 18, 38, 57, 76 120, 150 Peripheral arteries, below-the-knee balloon-expandable stents (Continued) Company Name Product Name Material Used Maximum Guidewire Size (inch) Introducer Size (F) Stent Diameter (mm) Stent Length (mm) Delivery (cm)

Terumo Introduces New Radial to Peripheral (R2P™) …

R2P MISAGO ® is a device within the Radial to Peripheral (R2P ) Portfolio, the first and only portfolio of longer-length radial devices specifically designed for peripheral procedures. 3 R2P MISAGO ® is the longest stent platform specifically designed for 3

Resolute Integrity Zotarolimus-Eluting Coronary Stent System …

Resolute Integrity Zotarolimus-Eluting Coronary Stent System Component Rapid Exchange Delivery System Small Vessel Medium/Large Vessel Available Stent Diameters (mm): 2.25, 2.5, 2.75 3.0, 3…

Bentley

The stent is available in lengths of 10, 13, 17, 20, and 24 mm. The novel stent system, developed by leading vascular technology company, Bentley (Hechingen, Germany), is aimed at treating babies with congenital heart disorders, which has a prevalence of

Two Different Successful Angioplasty Methods in Patients …

21/12/2012· There is no current guideline for percutaneous coronary angioplasty in stenotic ectatic coronary arteries because of the heterogeneity of the coronary artery morphology. We report two successful angioplasty cases in coronary artery ectasia with different clinical scenarios. One case showed

PI Product alog - Stents Vascular and Non-Vascular

PI-374604-AA PI alog MAY 2016 UPN / Order Code alog No. GTIN Stent Diameter (mm) Stent Length (mm) Sheath Compatibility (F) Guide Compatibility (F) heter Total Length (cm) C-Code H74937911415150 37911-41515 08714729390374 4 15 5 6 150 C1876

State of the Art: Which Stent for Which Lesion in …

The Strecker stent is made of a tubular wire mesh knitted from a single electropolished tantalum filament. It has a premounted balloon, and it has good radiopacity. The flexibility of this stent is a valuable feature. It is available in diameters from 4 to 12 mm with

Endovascular Today - Ask the Experts: Perfect Pairing: …

22/9/2017· Experts weigh in on properties of available stent technology and which coinations could be used to improve femoropopliteal disease outcomes. In the era of the “leave nothing behind” concept, in which the trend is to minimize stent use, the coination of drug-coated balloons (DCBs) with stents

E-LUMINEXX® Vascular Stents | Bard has joined BD

Product Item ID Product Item Name Diameter Length heter Length Guidewire heter Diameter Units/Each ZBM07020 E-LUMINEXX® Vascular Stent, 7 mm x 20 mm, 80 cm heter length, 6 Fr 7 mm 20 mm 80 cm 0.035″ 6F 1 ZBM07030 E-LUMINEXX

MISAGO 1: first-in-man clinical trial with Misago™ nitinol stent

The Misago (Terumo Corp., Tokyo, Japan) is the first peripheral nitinol self-expanding stent system with rapid exchange (RX) type delivery heter (Figure 1, 2, 3). The stent is made of a nickel-titanium alloy with three radiopaque markers at each end (for a total

Zenith Branch - Cook Medical

The length of the peripheral stent should be long enough to provide at least 10 mm overlap in the side branch device and at least 10 mm in the internal iliac artery (preferably 20-30 mm). The peripheral stent should land no further proximally than marker 2D in the sidebranch device.

Ultimaster™ Sirolimus Eluting Coronary Stent System

Stent design Open cell Stent material Cobalt Chromium L605 Strut thickness 80 μm Cell size (for 3 mm stent) 4.57 mm² Drug Sirolimus Drug dose 3.9 μg/mm stent length Polymer Poly (DL-lactide-co-caprolactone) Coating Abluminal & gradient 3-4 months

E-LUMINEXX® Biliary Stents | Bard has joined BD

Product Item ID Product Item Name Diameter Length heter Length Guidewire heter Diameter Units/Each ZBL04020 E-LUMINEXX® Biliary Stent, 4 mm x 20 mm, 135 cm heter length, 6 Fr 4 mm 20 mm 135 cm 0.035″ 6F 1 ZBL04030 E-LUMINEXX® Biliary

Lost and found: Coronary stent retrieval and review of literature

(Vascular Solutions, Minneapolis, MN), a 4.0 3 30 mm Synergy DES was unsuccessful in crossing the lesion due to heavy calcifiion. While retrieving the stent along with the GuideLiner, dissociation of the stent from its balloon/delivery system was noticed 2).

EverFlex- Self-Expanding Peripheral Stent System

The EverFlex Self-Expanding Peripheral Stent System .is intended to improve luminal diameter in the treatment of symptomatic de-novo or restenotic lesions up to 180mm in length in the native Superficial Femoral Artery (SFA) and/or proximal popliteal

Terumo Latin America

Peripheral Stent Large Image Misago ® Misago® is intended to be used for the treatment of stenotic or occlusive lesions in iliac or femoro-popliteal arteries to establish and to maintain patency. Download Brochure Product Characteristics

RX Acculink Carotid Stent System

The RX Acculink Carotid Stent System must be used with a guiding heter or introducer sheath to maintain adequate support of the 0.014” guide wire throughout the procedure. For best device performance, the guide wire exit notch should remain within the

Peripheral Stents - EverFlex | Medtronic

U.S. Indiions The EverFlex Self-Expanding Peripheral Stent System is intended to improve luminal diameter in the treatment of symptamotic de novo or restenotic lesions up to 180 mm in length in the native superficial femoral artery and/or proximal popliteal

Zilver® PTX® Drug-Eluting Peripheral Stent | Cook …

Handle of the Zilver PTX delivery system Zilver PTX Drug-Eluting Peripheral Stent Indied for improving luminal diameter for the treatment of de novo or restenotic symptomatic lesions in native vascular disease of the above-the-knee femoropopliteal arteries having reference vessel diameter from 4 mm to 7 mm and total lesion lengths up to 300 mm per patient.

Which is the best stent for angioplasty? - Quora

Before I go to the details of which stent is better, let me explain the evolution of Angioplasty a bit. Angioplasty was first done in 1977 using an elongated balloon to dilate the narrowed segment. The balloon was passed to the desired loion in

Bioabsorbable stenting in peripheral artery disease - …

Data on bioabsorbable stenting in peripheral artery disease are heterogenous and still controversial. > 50% stenosis or occlusion, < 15 mm length of lesion Rutherford 2–3 Type A, B, C 6–7 cm lesion length limit Rutherford 1–3, single lesion, length < 50 mm

Copyright © 2019. PH Plastic Group All rights reserved.sitemap