gas pipe under concrete slab in guinea

Gas pipe under concrete floor in kitchen | DIYnot Forums

3/9/2019· Hi, can a gas pipe be laid in a channel in concrete floor and then concreted over? Gas supply to a new hob in kitchen is over the other side of room so need to get supply over there. I''m doing all the prep work before the pluer comes to put the pipes in. So just

Can I concrete over gas pipe? - MyBuilder

Hi, the gas main from the street runs under the garden to the house. I''m wanting to put a driveway in for a car, can I concrete over the buried gas and water for that Sand or if the pipe will be encased in concrete, it would be better to invest in some rock wool and

Gas Line under patio, uncapped -

11/9/2016· This feature is not available right now. Please try again later.

I need to replace a leaking gas line, thats under a slab of …

I need to replace a leaking gas line, thats under a slab of concrete, I already removed some of the concret, and found - Answered by a verified Pluer We use cookies to give you the best possible experience on our website.

MDPE in concrete | PluersForums.net

25/10/2019· I''ve extended my mains water mdpe pipe through into my new extension and brought it up through the slab under the new kitchen window. However, I''ve had to change my kitchen window into a set of French doors and so the pipe is now in the way.

Gas pipe under concrete floor in kitchen | DIYnot Forums

3/9/2019· Hi, can a gas pipe be laid in a channel in concrete floor and then concreted over? Gas supply to a new hob in kitchen is over the other side of room so need to get supply over there. I''m doing all the prep work before the pluer comes to put the pipes in. So just

Natural gas pipe under concrete

Re: Natural gas pipe under concrete Author: hj (AZ) First you seal and test it to be sure there are no leaks. Then you unplug the vent so that if the pipe should develop a leak it will vent to a safe loion. One caveat is that propane CANNOT go under a concrete slab

How to Stub Out Pipes in Concrete Slab | Hunker

How to Stub Out Pipes in Concrete Slab By Cassandra Tribe SAVE Pipe stub outs are the sections of pipe that feed from the lines run underneath a slab or building, through the slab, then connect to appliances, or eventually continue on to the upper levels of

Gas line under slab - InspectionNews

7/3/2010· I am a Gas Safety Consultant. Several good points were made here, however I would like to add a couple more. IF code allowed a gas line under a slab or if someone just innocently poured concrete over a line to make a patio, drive way or sidewalk; these things

PE gas line under concrete slab - Pluing Zone - …

13/3/2013· Ok I have a job with outside BBQ and fire pit. They are going to pour it all with concrete so I have to be under slab. I have never installed gas piping undef slab but was checking my book and the only code I can find in my book seems to be regarding slabs within a

propane lines in slab? | Welcome to the Homesteading …

10/2/2010· I would run the gas through the wall. Also be sure when the pluer installs the pipes that he pressure tests them before the concrete covers them. Also be sure the toilet flange pipe and everything else is in the proper place because once the slab is poured it''s too

Pipes in concrete floor (gas and water) | DIY Doctor UK …

8/8/2007· You can bury pipes in concrete as long as they''re protected against corrosion, denso tape will be fine for the water pipes. The gas pipe should be factory coated (yellow) and have no joins or fittings underground, keeping the gas pipe in a duct would be handy, but

How to Stub Out Pipes in Concrete Slab | Hunker

How to Stub Out Pipes in Concrete Slab By Cassandra Tribe SAVE Pipe stub outs are the sections of pipe that feed from the lines run underneath a slab or building, through the slab, then connect to appliances, or eventually continue on to the upper levels of

Can I run a gas pipe in the floor? - MyBuilder

I have a gas meter (new 2010) under the stairs in the kitchen. At the moment it is just connected to one gas pipe which runs to the boiler but I want to run a pipe to the back of the cooker in the kitchen so that in the future I can have a gas oven/hob. (can''t afford to

How To Fix Leaking Pipes Under A Slab Foundation. - …

Loing the general area of the leak is necessary; once the area is loed, you will have to chisel through the concrete to the pipes in order to repair it. This article will explain to you how to fix leaking pipes under a slab foundation. Signs of a Slab Leak.

PE gas line under concrete slab - Page 3 - Pluing …

7/9/2013· Under slab gas line mikeplus General Pluing Discussion 5 10-18-2012 09:51 AM Lead 90 flush with concrete slab. How do i attach a new flange Drewp311 Residential Pluing 19 07-15-2012 09:29 AM Gas line in sewer OldSchool Drain and Sewer 18 10

Concrete slab - Laying pipes

It is best to avoid running pluing pipes through the slab. However, this may occur when the pipe discharge level is critical and there is no other means to maintain sufficient height. Section showing pipe laid through slab Hot water heating pipes may be

Building footings over main gas and electric pipes | …

15/11/2010· We would confirm what FM has said, we have worked on numerous sites where the gas and electric are brought into the garage The gas service was sleeved 450 deep under the slab either through a 100mm plastic pipe or 63mm single wall yellow gas duct, up

Loe Pipe Under a Concrete Slab | Tools of the Trade

Loe Pipe Under a Concrete Slab Layout Tools Posted on: Noveer 16, 2015 Loe Pipe Under a Concrete Slab Kitchen and bath remodels in houses built on concrete slabs offer their own unique set of challenges, not the least of which is tying the new

Concrete slab - Laying pipes

It is best to avoid running pluing pipes through the slab. However, this may occur when the pipe discharge level is critical and there is no other means to maintain sufficient height. Section showing pipe laid through slab Hot water heating pipes may be

Domestic Gas Pipework - Initiative copper

Gas pipe behind plasterboard Individual adhesive dabs Continuous dabs to surround pipe Full length tier batten Ply sheathing Gas pipe behind plasterboard Insulation Concrete slab Chipboard over insulation Pipe laid in insulation layer Precast beam & block

PVC pipe buried directly in concrete? - Google Groups

22/8/2008· I have a contractor who insists he wants to bury PVC directly in a slab. I know this is wrong the concrete makes both PVC pipe and cement at fittings brittle, and they fail with the slightest expansion or contraction. I have looked everywhere on the web for a

If all the pluing drains have water in them and you can …

3) If a waste drain pipe has fractured under the the concrete floor of your home, that can also allow sewer gas to rise up through cracks in the floor slab. it may not be as easy to this one track down though, until sufficient wetness permeates the floor slab.

Gas pipe in concrete | PluersForums.net

24/11/2012· No guys, the floor in the house is being raised. It will be done in concrete but the screed on top. It''s quite hard to explain the layout but there''s no other way the pipe can be laid, so a small section, 1 meter will need to go across and then up through the concrete.

gas pipe under concrete slab - Fine Homebuilding

7/7/2012· I am building a building which is on a concrete slab. I want to put a gas line for propane under the slab. Can I do this? If so what material should i use for the pipe and what stipulations are there when doing this? Thanks for the help

Gas Service Guidebook - LADBS

Preface For over 100 years, SoCalGas has strived to provide outstanding customer service and be a positive community influence. Our customers have come to expect our exceptional service and this gas service guidebook was written with that commitment in mind.