The metal water pipe can be bonded to the electrical service enclosure, the grounded conductor at the service, the grounding electrode conductor where it is of sufficient size, or to one or more of the grounding electrodes for the service.

Gas meter not bonded, what diameter …

24/1/2016· it may be bonded as the pipe enters the building, which is acceptable, there''s a difference between cross bonding, which some people have where the pipes underneath the boiler are all bonded together for example, and MEB which is cold main, gas, and electric

Gas Meter Grounding Deemed Ok By The Gas Company - …

27/7/2016· I shot a video prior to starting this channel where I double grounded my gas meter. Several people expressed a concern that the wire going into the ground was to be used for tracing the gas line and not as a ground. I called the gas company and they stated that it would cause no harm and may even help in the event of a

Bonding Metal Piping Systems - IAEI News magazine

Extracted text from NFPA 54-2002 6.13 Electrical Bonding and Grounding. 6.13.1 Each aboveground portion of a gas piping system that is likely to become energized shall be electrically continuous and bonded to an effective ground-fault current path. Gas piping

Bonding Gas Piping | CPT

Old-school bonding for gas piping Way back in time before we had all of this new-fangled gas equipment like forced air furnaces, the gas-fired equipment in our homes was simply gas-fired equipment. Electricity didn’t play a role, just like electricity still doesn’t.

Is Gas Pipe Grounding Legal? | Electrical Construction & …

1/3/2000· Is Gas Pipe Grounding Legal? You must not use an underground metal gas piping system as a grounding electrode. So, what''s the confusion all about? The controversy behind bonding and grounding metal gas piping systems arose when many electrical professionals questioned the …

Bonding to gas and water - MyBuilder

If you want your earth up to date then yes get it done, that answer from ark installations is not correct if you have a earth rod then that should be 10mm, and all earthing does not have to be the same size, your main earth should be 16mm, your earth bonding 10mm

What should it cost to install bonding wire on gas piping …

You can easily do it yourself. First look in your garage at the incoming water and gas piping to see the size. The incoming lines would normally be 1″. Buy a bronze or copper bonding clamp for 1″ water pipe and for a 1″ gas pipe. Check the lines t

Practice for good grounding and bonding a home wiring …

19/6/2017· Gas pipe in older homes is usually steel or copper. The bonding connection point for these pipes can be at any accessible loion, such as at the water heater or at the gas meter. Gas pipe in some new homes is a flexible material called corrugated stainless.

POCKET GUIDE 13 - Elecsa

POCKET GUIDE 13 This Guide gives information on the sizing of main protective bonding conductors, based on the requirements given in Regulation Group 544.1 of BS 767 1. Protective equipotential bonding is a provision under the requirements for fault protection

What is the difference between Bonding, Grounding and …

27/9/2012· Go to Content ↑ Bonding Bonding is simply the act of joining two electrical conductors together. These may be two wires, a wire and a pipe, or these may be two Equipments. Bonding has to be done by connecting of all the metal parts that are not supposed to be

FACT SHEET - American Gas Association

segment of rigid gas pipe or CSST fitting to any one of the options listed. The conductor length is limited to a maximum of 75 ft. Table 250.66contains the minimum size for the bonding conductor which may be larger than the NFGC’s minimum requirement of

gas line not bonded/grounded - Electrical Inspections - …

19/4/2019· The bonding is achieved through the gas valve and cabinet metal to the EGC (green wire spliced to the copper) inside the furnace. If no furnace or equipment is present to allow for a mechanical bond to the EGC then it is incorrect. Starting in Sept. 2007, many AHJ’s

Earth bonding size | DIY Doctor UK DIY Forums

27/7/2008· Min size of any earth cable no protected is 4mm² 543.1.1 (v) + 544.2.1 The PEN cable has a min size of 10 mm² 543.4.3 (Not really anything to do with you) Main protective bonding conductor min 6 mm² 544.1.1 Where PME conditions apply it is dependent on

Water Heater Bonding Wire—Is it Needed? - The Spruce

Another school of thought is that the bonding wire helps to complete the electrical ground of the entire pluing system. Metal pipes are required by code to be electrically grounded, and this is normally done by grounding the cold water inlet pipe to the home. The

Bonding & Grounding Wire & Accessories - Wire & …

Bonding and grounding wire and accessories help prevent the unsafe buildup of static electricity, reducing the risk of electric shock to workers and damage to equipment through explosions or fires. Bonding wire is used to create electrical connections between two

NOTICE - GAS PIPE BONDING

NOTICE GAS PIPE BONDING CSSR (CORRUGATE STAINLESS STEEL TUBING) 2009 IFGC 310.1 AND 2009 IRC G2411.1 NOTE: THIS IS AN ADDITION TO 2009 IFGC 310.1 AND 2009 IRC G2411.1 GAS PIPE BONDING CSST gas piping systems shall be

Grounding vs Bonding - Part 10 of 12 | Electrical …

1/10/2005· Size this metal water piping-bonding jumper per Table 250.66, based on the largest ungrounded conductor of the SDS. You don''t need a water pipe bonding jumper, if you: Use the water pipe as the grounding electrode for the SDS, or

Earth Bonding to incoming gas | Screwfix Community …

20/2/2011· Hello all. Just a quick question. The main gas meter is in the front garden of the house, it has no earth bonding. To run a 16mm earth cable from this, all the way through the house to the earth block in the electric cupboard at the other end of the house would be a

Bonding Water Piping: Is It A Metal System or Not? | …

The metal water pipe can be bonded to the electrical service enclosure, the grounded conductor at the service, the grounding electrode conductor where it is of sufficient size, or to one or more of the grounding electrodes for the service.

Practice for good grounding and bonding a home wiring …

19/6/2017· Gas pipe in older homes is usually steel or copper. The bonding connection point for these pipes can be at any accessible loion, such as at the water heater or at the gas meter. Gas pipe in some new homes is a flexible material called corrugated stainless.

Bonding - WireYourOwnHouse.Com

The method of bonding these systems is essentially the same as grounding to your ground rods. Simply run the proper sized wire, connect to the clamp that you have secured to the pipe, and connect the other end to the ground bar at the main breaker panel or

Earth bonding size | DIY Doctor UK DIY Forums

27/7/2008· Min size of any earth cable no protected is 4mm² 543.1.1 (v) + 544.2.1 The PEN cable has a min size of 10 mm² 543.4.3 (Not really anything to do with you) Main protective bonding conductor min 6 mm² 544.1.1 Where PME conditions apply it is dependent on

Electrical bonding requirements for gas piping systems | …

CSA B149.1-15 Natural Gas and Propane Installation Code (B149.1) clause 4.7.3 requires that interior metal gas piping or tubing that may become energized shall be made electrically continuous and shall be bonded in accordance with Canadian Electrical Code

CSST gas line bonding? | The Building Code Forum

23/3/2019· [IMG] Would this bonding be allowed on a CSST gas line. The bonding wire is on the steel gas pipe and not on the brass fitting connector. No. Solid #6 attached upstream of the CSST and taken to the grounding electrode system. There is a CSST manufacturer

Earth Bonding Cable Size Selection | Eland Cables

Notes: 1. Protective conductors (including earth and bonding conductors) of 10mm² cross-sectional area or less shall be of copper. 2. The distributor may require a minimum size of earth conductor at the origin of the supply of 16mm² copper or greater for TN-S and