gas pipe bonding wire size in morocco

Electrical bonding requirements for gas piping systems | …

CSA B149.1-15 Natural Gas and Propane Installation Code (B149.1) clause 4.7.3 requires that interior metal gas piping or tubing that may become energized shall be made electrically continuous and shall be bonded in accordance with Canadian Electrical Code

POCKET GUIDE 13 - Elecsa

POCKET GUIDE 13 This Guide gives information on the sizing of main protective bonding conductors, based on the requirements given in Regulation Group 544.1 of BS 767 1. Protective equipotential bonding is a provision under the requirements for fault protection

Sizing main protective bonding conductors, advice and

29/1/2016· In many ways, determining the size of the main protective bonding conductors in a TN-C-S system is much simpler. The installer should always be wary about choosing to use the steel wire armouring of a cable as a main protective bonding conductor.

Bonding of CSST Gas Piping Systems - Texas Inspector

steel pipe, and copper tubing. However, CSST represented a major breakthrough in gas piping far beyond its obvious flexible physical characteristics. The departure from conventional practice was that for the first time the gas piping was treated as a

Earthing and Bonding | Electrical Safety First

Main bonding - Green and yellow conductors that connect metal pipes (gas, water or oil) from inside a building to the main earthing terminal of the electrical installation. Main bonding connections may also be made outside the building, for example where a semi-enclosed gas meter box is installed outside and it is not possible to install a bond to the gas installation pipework indoors.

Is Gas Pipe Grounding Legal? | Electrical Construction & …

1/3/2000· Is Gas Pipe Grounding Legal? You must not use an underground metal gas piping system as a grounding electrode. So, what''s the confusion all about? The controversy behind bonding and grounding metal gas piping systems arose when many electrical professionals questioned the …

IET Forums - Bonding of Water and Gas Supplies

25/2/2016· Hi, I have been looking at an electrical inspection report for a family friend that was completed for their local church. Within the report it notes that the earthing and bonding for the water and gas supplies require rectifiion as they are not direct to the earth bar.

Earth Bonding, what size wire? | DIY Doctor UK DIY Forums

27/3/2009· HI, Can someone please advise me on the correct size of wire to use for supplementary earth bonding in bathrooms and is it different to the size used for the Earth Bonding on the stop cock and gas???? Sorry if this has been covered before! Cheers

Domestic Earth bonding requirements - MyBuilder

Most s will need 16mm bonding into the fuse board and 10mm to the water and gas. The earth cable is green and yellow. I always try to get an earth bond to gas and water unless they are entirely in plastic. We recommend the fuse board has one or

Grounding and Bonding of Gas Piping | Electrical …

Judging by the responses to NECA’s online “Code Question of the Day (CQD),” gas piping and its use in bonding and grounding sure generated controversy and explosive comentary. The following questions and answers should clarify what many readers are asking.

CSST gas line bonding? | The Building Code Forum

23/3/2019· [IMG] Would this bonding be allowed on a CSST gas line. The bonding wire is on the steel gas pipe and not on the brass fitting connector. No. Solid #6 attached upstream of the CSST and taken to the grounding electrode system. There is a CSST manufacturer

Electrical Bonding of Gas Piping Systems | American Gas …

This American Gas Association fact sheet provides an overview of the requirements for the electrical bonding of fuel gas piping systems to the electrical grounding system based on ANSI Z223.1/NFPA 54, National Fuel Gas Code - 2018 (NFGC). The bonding

FACT SHEET - American Gas Association

segment of rigid gas pipe or CSST fitting to any one of the options listed. The conductor length is limited to a maximum of 75 ft. Table 250.66contains the minimum size for the bonding conductor which may be larger than the NFGC’s minimum requirement of

the Regs: BS7671 17th Edition Online Course - Protective …

Remeer when you get a non standard conductor size using this table you must round up to the next size available. Main Bonding Conductor Sizes… For protective bonding conductors in a TN-S or TT supply it’s (Regulation 544.1.1) half the size of the main

250.104(B) - Bonding of Gas Piping

Page 1 of 2 NC Department of Insurance Office of the State Fire Marshal - Engineering Division 1202 Mail Service Center, Raleigh, NC 27699-1202 919-647-0001 Bonding of Gas Piping Code: 2014 Electrical Code Date: February 5, 2018 Section: 250.104(B)

Earth bonding size | DIY Doctor UK DIY Forums

27/7/2008· Now main bonding to gas and water services must be connected within 600mm of stop tap and supply from gas meter. earth bonding wire size by newartist » Wed Apr 25, 2007 3:21 pm Last post by newartist Thu Apr 26, 2007 12:10 pm Replies 2 Views 2886

Bonding Metal Gas Piping - IAEI News magazine

Metal gas piping bonding is not included in these requirements but is included in 250.4(A)(4) and (B)(3). Specific NEC Bonding Requirements Electrical bonding is addressed in the NEC in Part V of Article 250. The section dealing with bonding metal gas piping is

NOTICE - GAS PIPE BONDING

NOTICE GAS PIPE BONDING CSSR (CORRUGATE STAINLESS STEEL TUBING) 2009 IFGC 310.1 AND 2009 IRC G2411.1 NOTE: THIS IS AN ADDITION TO 2009 IFGC 310.1 AND 2009 IRC G2411.1 GAS PIPE BONDING CSST gas piping systems shall be

Practice for good grounding and bonding a home wiring …

19/6/2017· Gas pipe in older homes is usually steel or copper. The bonding connection point for these pipes can be at any accessible loion, such as at the water heater or at the gas meter. Gas pipe in some new homes is a flexible material called corrugated stainless.

Domestic

17/11/2011· I have just been informed by my electrician that we have to bond our gas pipe. The problem is that the gas meter is within a housing on the front external wall of my This thread looks familiar but i will say it again earthing and bonding perform different functions E

Is Gas Pipe Grounding Legal? | Electrical Construction & …

1/3/2000· Is Gas Pipe Grounding Legal? You must not use an underground metal gas piping system as a grounding electrode. So, what''s the confusion all about? The controversy behind bonding and grounding metal gas piping systems arose when many electrical professionals questioned the …

Domestic

17/11/2011· I have just been informed by my electrician that we have to bond our gas pipe. The problem is that the gas meter is within a housing on the front external wall of my This thread looks familiar but i will say it again earthing and bonding perform different functions E

Grounding vs Bonding - Part 10 of 12 | Electrical …

1/10/2005· Size the metal water pipe bonding jumper per Table 250.66, based on the largest ungrounded service conductor. Here''s an easy pop quiz for you. What size bonding jumper must you use for the metal water piping system, if the service conductors are 4/0 AWG

400 amp service/ grounding and bonding - Electrician …

27/10/2016· I am doing a 400 amp service does this seem the correct way to do it peco are bringing direct burial wires underground to my meter socket, I am going pipe into the bottom of my 320 meter socket. I 400 amp service/ grounding and bonding - Electrician Talk - …

CSST bonding requirements (another update) - Structure …

The other end of that wire shown above went into the main electric panel. The video below, produced by Gastite, shows a couple of examples of properly bonded CSST. While the old method for bonding CSST required a connection at the main electric panel, this is

Bonding of Gas Lines Electronic Copy - Surrey

Septeer, 2013 ELECTRICAL SECTION BONDING OF GAS LINES BC Electrical Code rule 10-406(4) requires interior metal gas lines to be bonded. The increased use of soft copper tubing for interior gas lines has resulted in some practical problems for